Suzhou Hangruisi Measurement and Control Technology Co., Ltd.

Force Control System Solutions Provider

+
  • WL101.png
  • 40-1.jpg

HRS-WL101 load cell

Category:

Weighing Sensor Series

Cantilever beam load cell

  • Product Description
  • Download Data

    Product features

    ● Aluminum alloy construction, high precision, and excellent repeatability.

    ● Parallel beam structure, accuracy class C3

    ● Widely applicable to batching systems, packaging scales, hopper scales, and various high-precision industrial automation weighing and measurement control systems.

     

    Technical Specifications

    Rated Capacity/Capacity

    300,500g;1,2,3,5kg

    Output sensitivity / Rated output

    1.0±10%mV/V(0.3,0.5kg)
    2.0±10%mV/V(1-5kg)

    Zero Output / Zero Balance

    ±0.02 mV/N

    Creep (30 min)

    ≤0.0166%F.S.

    Non-linearity

    ≤0.015%F.S.

    Hysteresis

    ≤0.015%F.S.

    Repeatability

    ≤0.015%F.S.

    Input resistance / input impedance

    380±40Ω

    Output impedance

    380±40Ω

    Zero-point temperature drift / Temp. effect on zero

    0.02%F.S./10℃

    Temperature sensitivity drift / Temp. effect on output

    0.017%F.S./10℃

    Recommended excitation voltage

    5-15V

    Operating Temp Range

    -25-70℃

    Safe overload

    150%F.S.

    Ultimate Overload

    200%F.S.

    Insulation resistance

    ≥5000M/100V(DC)

    Reference Max. Platform Size

    120*120mm

    Cable size

    φ4×350mm

    Cable connection mode

    1 type: black power cable – green or blue power wire + white signal + red signal –
    2 types: black power supply – red power supply + green or blue signal + white signal –

     

    Floor Plan/Plan (Unit: mm)

     

    Load direction