Suzhou Hangruisi Measurement and Control Technology Co., Ltd.

Force Control System Solutions Provider

+
  • HRS-WL105.png
  • 44-1.jpg

HRS-WL105 load cell

Category:

Weighing Sensor Series

Cantilever beam load cell

  • Product Description
  • Download Data

    Product features

    ● Made of aluminum alloy for a long service life.

    ● Phase angle correction, protection rating IP66

    ● Widely applicable to batching systems, packaging scales, hopper scales, and various high-precision industrial automation weighing and measurement control systems.

     

    Technical Specifications

    Rated Capacity/Capacity

    30kg-300kg

    Output sensitivity / Rated output

    2.0±10%mV/V

    Zero Output/Zero Balance

    ±0.02 mV/N

    Creep (30 min)

    ≤0.023%F.S.

    Non-linearity

    ≤0.017%F.S.

    Hysteresis

    ≤0.017%F.S.

    Repeatability

    ≤0.017%F.S.

    Input impedance

    405±15Ω

    Output impedance

    350±3Ω

    Zero-point temperature drift / Temp. effect on zero

    0.03%F.S./10°C

    Temperature sensitivity drift / Temp. effect on output

    0.03%F.S./10°C

    Recommended excitation voltage

    5-15V

    Operating Temp Range

    -10-40°C

    Safe overload

    150%F.S.

    Ultimate Overload

    200%F.S.

    Insulation resistance

    ≥5000M/100V(DC)

    Maximum Platform Size/Reference Max.Platform Size

    450*450mm

    Cable size

    ①4×3000mm

    Cable connection mode

    ExC+ Red; ExC- Black;

    Sig+: Green; Sig-: White

     

    Floor Plan/Plan (Unit: mm)

     

    Load direction