HRS-D505 Industrial Control Instrument
Category:
Instrumentation/Transmitter Series
Display instrument
Tel: 0512-66219558
Email: info@hangruisi.com
- Product Description
- Download Data
-
Product features
● Used in applications that require converting force measurement signals into digital communication signals, standard analog output signals, and simple control.
● Analog output signals can be selected from 0–20 mA, 4–20 mA, 0–5 V, or 1–5 V; the digital communication interface can be RS‑485 or RS‑232, both with isolation.
● The controller features upper‑limit, mid‑range, and lower‑limit threshold detection; for detailed control functions, please refer to Note 3 in the user manual.
● The limit output offers three operating modes: upper‑limit, lower‑limit, and both‑upper‑and‑lower‑limit detection. For detailed explanations, please refer to Note 2 in the user manual.
● The controller is powered by a 24 V DC supply with a voltage tolerance of ±5 V, ensuring greater safety and stability.
Technical specifications
*1. Display window: dual-row 6-digit LED display, with character heights of 9 mm and 7.5 mm, respectively.
*2. Graduation values: 1, 2, 5, 10, 20, 50
*3. Maximum weighing display range: 999,999
*4. Decimal place: 0, 0.0, 0.00, 0.000, 0.0000, 0.00000
*5. Static accuracy class: Resolution 900,000, accuracy 0.01%
*6. Maximum signal input range: -3.6 mV/V to 3.6 mV/V (equivalent to -18 mV/V to 18 mV/V)
*7. Zero Drift: ≤0.05 μV (@0.02 mV/V)
*8. Span temperature coefficient: ≤10 ppm/°C
*9. Sensor interface input impedance: ≥20 MΩ
*10. Nonlinearity error: ≤0.002%FS
*11. A/D conversion rate: 400 samples per second
*12. Zero Drift: ≤10 μV/°C
*13. Span Temperature Coefficient: ≤0.02%FS/°C
*14. Sensor Type: Strain-Gauge Sensor
*15. Sensor excitation voltage: DC 5 V, 100 mA; up to four 350 Ω sensors can be connected in parallel.
*16. Digital output (contact) capacity: Relay output capacity: AC 220 V, 1 A, 6 channels; Transistor output capacity: DC 24 V, 0.5 A.
*17. Digital input voltage: DC 24 V
*18. Digital input current: 4–6 mA
*19. Power supply range: DC 24 V (±5)
*20 Product power: ≤10W
*21. Operating temperature: -10℃ to 50℃
*22. Temperature range: ≤90% relative humidity (no condensation)
Load direction

Floor Plan/Plan (Unit: mm)