HRS-B6 Intelligent Weighing Controller
Category:
Instrumentation/Transmitter Series
Display instrument
Tel: 0512-66219558
Email: info@hangruisi.com
- Product Description
- Download Data
-
Product features
● The input employs a fully isolated 24-bit AD converter, with a measurement accuracy of 0.05% F.S.
● A unique digital filtering function allows for accurate measurements even in vibrating environments—simply increase the digital filter parameters to achieve optimal performance.
● Communication protocol is optional; choose either Modbus RTU or ASCII.
Technical Specifications
*1. Standard sampling rate: 25–50 samples per second; if a higher sampling rate is required, please specify when placing your order.
*2. The communication port employs opto-isolation; RS232 and RS485 are optional—please specify when placing your order.
*3. Display range: Measurement display range: -199,999 to 200,000; decimal point position is user‑adjustable.
*4. Analog inputs: 0–20 mA, 4–20 mA, 0–5 VDC, 1–5 VDC, 0–10 VDC, –5 VDC to 5 VDC, –10 VDC to 10 VDC, mV signals, etc.; please specify when placing your order.
*5. Transmitter output:
Opto-isolation, with outputs such as 4–20 mA and 0–10 V.
Output resolution: 1/4000; accuracy better than ±0.2% F.S.; load capacity: ≤600 Ω
*7. External power supplies of 24 VDC, 12 VDC, 5 VDC, or precision low‑temperature‑drift power supplies such as 10 V precision and 12 V precision; please specify when placing your order.
*8. Alarm: Up to 4 alarm relay outputs; please specify when placing your order.
*9. Equipped with a panel-mounted button for zeroing; the zeroing method is user-configurable.
*10. Equipped with peak and valley detection, it saves the maximum and minimum values recorded during the measurement process.
*11. Features manual zeroing of peak and valley values: when the panel’s zero‑reset button is pressed, or when the external zero‑reset switch is closed, the measured value is reset, and both the peak and valley values are cleared, restarting the calculation of peak and valley readings.
*12. Equipped with an automatic peak‑reset function, ideal for applications requiring continuous maximum‑value monitoring; no manual intervention is needed, as the previous peak value is automatically cleared.
*13. Power Supply: For instruments powered by 220 VAC, the input voltage range is 100 VAC to 245 VAC, with a power consumption of less than 7 VA.
*14. Operating environment: -10°C to 70°C, with relative humidity below 90% RH (for instruments designed for high and low temperature ranges, please specify at the time of order)