Commodity name:
HRS-D508 Industrial Control Instrument
Product features
● Low-power design for longer battery life
● 6-digit, 20 mm character height LCD display
● Comprehensive features: low-voltage battery voltage detection with alerts, power‑off retention of settings, and weight lock.
● Idle mode, automatic shutdown, zeroing, and tare functions
● Optional serial port output for connecting to a large display or computer
Technical Specifications
Basic specifications:
| Project |
Specifications |
| Power supply voltage |
AC power supply |
100~240V AC 50/60Hz |
| AC/DC power supply |
10~24V AC 50/60Hz;10-24VDC |
| Power consumption |
AC power supply |
8 VA or less |
| AC/DC power supply |
AC: below 7 VA; DC: below 6 W |
| Permitted voltage variation range |
90% to 110% of the supply voltage |
| Insulation resistance |
≥100 MΩ (500 VDC MEGA reference) |
| Dielectric strength |
2000V AC (Test conditions: 50/60 Hz, 1 minute) |
| Anti-interference |
EC61000-4-2 (Electrostatic Discharge), Level III EC61000-4-2 (Electrical Fast Transient/Burst), Level III EC61000-4-2 (Surge), Level III |
| Protection rating |
P65 (Front Panel Protection of the Product) (GB/TG42-2008) |
| Operating environment |
Ambient temperature |
-10~55℃ (storage: -25~65℃) |
| Environmental humidity |
35~85℃ R.H., no condensation |
| Installation location |
Indoor, altitude < 2000 m |
Input specifications:
| Project |
Specifications |
| Measure and control speed |
0.1 seconds per channel |
| Basic error |
±0.2%F.S |
| Display Range |
-99999~99999 |
| Number of channels |
1–4: Up to 4 channels can be selected. |
| Input signal type |
Resistance thermometer |
Pt100/Cu100/Cu50/BA2/G53 |
| Thermocouple |
K/S/R/B/N/E/J/T |
| Direct current |
4~20mA/0~10mA/0~20mA |
| Direct current voltage |
0~5V DC/1~5V DC |
| millivolt |
±100 mV |
| Remote pressure gauge |
| Input signal type |
Smooth filtering (moving average filtering), digital filtering (inertia… Sexual filtering), mutation delay filtering |
Optional specifications:
| Project |
|
| Alarm Output |
T1-T4 |
1–4-point relay preset output, 250 V AC/3 A, resistive load |
| Analog output Resolution: 1/3000 |
A1 |
Current output: 4–20 mA, 0–10 mA, 0–20 mA; two channels, A1A1. |
| A2 |
Voltage output (1–5) V, (0–5) V, 2 channels: A2A2 |
| A3 |
Voltage output (0–10 V), 2 channels, A3A3 |
| Communication interface |
S1 |
RS232 interface, TC ASCII protocol |
| S2 |
RS485 interface, TC ASCII protocol |
| M1 |
RS232 interface, Modbus-RTU protocol |
| M2 |
RS485 interface, Modbus-RTU protocol |
| External power supply |
B1 |
24V±5%, below 50mA |
| B1G |
24V ±5%, below 100mA |
| B2 |
12V±5%, below 50mA |
| B2G |
12V ± 5%, below 100mA |
| B3 |
Precision power supply, typically 10 V ±2%, 30 ppm, and less than 100 mA. |
| USB dump interface |
USB |
USB dump |
| Print interface |
P |
Hardware clock |
Floor Plan/Plan (Unit: mm)